8
Operation
Status and error messages
Operating Instructions – MOVIPRO
®
PHE..B-A15-.1X0..B-00
71
8.4
Status and error messages
The status display of the device displays the following information depending on para-
meterization and operating state:
•
In automatic operation:
– Active drive command or active drive command and speed limitation
•
in manual operation:
– Active command
•
In error status:
– Err or ErP
– Error code
•
When establishing a connection with the IR remote control:
– Vehicle ID
•
In all other operating states:
– Operating state
For detailed information about possible status messages, refer to the relevant soft-
ware documentation and the project description of the system solution, chapter "Oper-
ation".
8.4.1
List of faults
In case of a malfunction, the status display of the device displays the following error
codes.
Code
Meaning
Possible cause
Measure
302
Overcurrent
•
Short circuit at frequency in-
verter output
•
Check the connection between the
frequency inverter output and the
motor as well as the motor winding
for short circuits.
•
Reset the fault by switching off the
DC 24 V supply voltage or resetting
the error.
303
Thermal overload of
the output stage or
internal device error
•
Heat sink is dirty
•
Clean the heat sink.
•
Reset the fault by switching off the
DC 24 V supply voltage or resetting
the error.
•
Ambient temperature too high •
Lower ambient temperature.
•
Reset the error by switching off the
24 V supply voltage or via error re-
set.
•
Heat build-up in frequency in-
verter
•
Prevent heat build-up.
•
Reset the error by switching off the
operating switch.
•
Drive load too high
•
Reduce the load on the drive.
•
Reset the error by switching off the
operating switch.