5
Mechanical installation
Requirements
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
44
5
Mechanical installation
5.1
Requirements
WARNING
Risk of crushing if the load falls.
Severe or fatal injuries.
•
Do not stand under the load.
•
Secure the area where loads can fall down.
•
Trained specialists perform the installation.
•
The information provided in the technical data and the permitted conditions for the
operating location of the device are observed.
•
The minimum clearance and the required gaps for using a mounting plate are
complied with. For more information, refer to chapter "Minimum clear-
ance" (→
•
The device is only mounted using the intended mounting options.
•
The selection and dimensioning of the mounting and locking elements are in line
with the applicable standards, the technical data of the devices and the local re-
quirements.
•
The bore dimensions are calculated in line with the respective type of fixture. For
more information, refer to chapter "Assembly" (→
49).
•
The mounting and locking elements fit into the existing bores, threads and counter-
sinks.
•
All display and actuator elements are visible and accessible after installation.
•
The device is positioned in a way that it will not collide with other components or
design elements along the travel path.
•
Fasten the device so that it is not exposed to shocks or vibrations during operation
that exceed loads according to DIN EN 60721-3-3/-5 3M7/5M2.
26596598/EN – 10/2020
Содержание MOVIPRO PHC2 Series
Страница 2: ...SEW EURODRIVE Driving the world...
Страница 185: ...Index X5502 143 26596598 EN 10 20 Operating Instructions MOVIPRO PHC2 A A M1 E45C C5 185...