10
Technical data
General
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
165
10.2
General
Basic device
Size
Size 1
Size 2
Performance class
2.2 kW/4 kW/7.5 kW
11 kW/15 kW/22 kW
Interference immunity
Complies with EN 61800-3
Interference suppression level A to EN 55011
Interference emission
Limit value class C3 to EN 61800-3
Ambient temperature
ϑ
U
+5 – +40 °C
Non-condensing, no moisture condensation
Device is intrinsically safe with respect to temperature. When the
temperature of the heat sink is too high, the device switches off and
the error message "Overtemperature" is issued.
Ambient temperature derating
EN 60721-3-3
Climate class
Class 3K3
Storage temperature
ϑ
L
-25 – +70 °C
Degree of protection
IP54
Restrictions in use / installa-
tion altitude
•
Up to h < 1000 m without restrictions.
•
The following restrictions apply to heights ≥ 1000 m:
– From 1000 m to max. 4000 m:
I
N
reduction by 1% per 100 m
– From 2000 m to max. 4000 m:
U
N
reduction by AC 6 V per 100 m
Mass
21 kg
35 kg
Dimensions W × H × D
570 × 300 × 189 mm
660 × 420 × 202 mm
10.3
Input data
Basic device
X121.
Size
Size 1
Size 2
Performance class
2.2 kW
4 kW
7.5 kW
11 kW
15 kW
22 kW
Power supply
Three-phase current
Input voltage range
3 × AC 380 – 500 V
Line frequency
f
line
50 – 60 Hz
Supply current
(at U
line
= 3 × AC 400 V)
I
line
AC 5 A
AC 8.6 A AC 14.4 A AC 21.6 A AC 28.8 A AC 41.4 A