![SEW-Eurodrive MOVIPRO ADC Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/sew-eurodrive/movipro-adc/movipro-adc_operating-instructions-manual_1250122051.webp)
6
Mechanical installation
Minimum clearance
Operating Instructions – MOVIPRO
®
ADC
51
6.3.2
Horizontal installation
The following figure shows the minimum clearance of the device:
E
C
D
B
A
F
45035996737809931
The following table lists the minimum clearances:
Clearance
Function
Size
A: Device cover
Space for display elements, diagnostics
elements and actuator elements, such as
service unit
≥ 150 mm
B: To the side on the right
Space for connection cables, plug connect-
ors, mounted elements and actuator ele-
ments, e.g. maintenance switch
See dimension drawings in
chapter "Technical
data" (→
•
Without connection cable or
mounting elements: ≥ 30 mm
•
With interface box: ≥ 200 mm
•
With connection for device
supply: ≥ 250 mm
C: To the front
Space for connection cables, plug connect-
ors
See dimension drawings in
chapter "Technical
data" (→
D: Below the cooling fins
Space for optimum heat convection
The cooling fins must not be located in a
closed hollow space.
≥ 15 mm
E: To the side on the left
Space for optimum heat convection
≥ 30 mm
F: To the back
Space for optimum heat convection
≥ 30 mm
22749055/EN – 04/2016