4
Device structure
Field distributor
Manual – PROFINET IO Interfaces, Field Distributors
19
4.3.2
MF../Z.6., MQ../Z.6. field distributors
X2
X1
1
X1
2
X1
3
X1
4
X1
5
X1
6
X3
[4]
[1]
[2]
[3]
[5]
[6]
[7]
[8] [3] [9]
9007200390944651
[1] 6 x M20 x 1.5 (delivery includes 2 EMC cable glands)
For DeviceNet™: Micro-style connector/M12 connector (X11)
[2] 2 x M25 x 1.5
[3] Connection PE/equipotential bonding
[4] Hybrid cable connection; connection to MOVIMOT
®
inverter (X9)
[5] Maintenance switch
with line protection
(triple lock, color: black/red)
Only for MFZ26J design: Optional integrated feedback for position of the mainten-
ance switch.
The feedback is evaluated at digital input DI0 (see chapter "Connection of field-
bus interface inputs/outputs").
I
O
N
I
ON
0 OFF
0 OFF
Ø 5 – Ø 8 mm
[6] Terminals for power supply and PE connection (X1)
[7] Terminals for bus, sensor, actuator, 24 V connection (X20)
[8] Pluggable terminal "Safety Power" for 24 V MOVIMOT
®
supply (X40)
[9] Terminal block for 24 V through-wiring (X29),
internal connection to 24 V on X20
22870857/EN – 12/2016