Supplementary field distributor startup information
MF../Z.6. field distributor
Manual – PROFINET IO Interfaces, Field Distributors
134
11
Supplementary field distributor startup information
The startup procedure is described in the chapter "Startup".
In addition, observe the following notes on the startup of field distributors.
11.1
MF../Z.6. field distributor
11.1.1
Maintenance switch
The maintenance/line protection switch of the Z.6. field distributor protects the hybrid
cable against overload and switches the following supplies:
•
Power supply and
•
DC 24 V supply
WARNING
Electric shock caused by dangerous voltages in the connection box and field distrib-
utor.
The maintenance/miniature circuit breaker disconnects only the MOVIMOT
®
drive
from the power supply system, not the field distributor.
•
Disconnect the field distributor from the power supply. Observe the minimum
switch-off time after disconnection from the supply system:
–
1 minute
Block diagram:
[1]
"Safety Power”
RS485
X1
X20/X29
MF../MQ..
X40
L
1
L
2
L
3
2
4
V
G
N
D
2
4
V
G
N
D
R
S+
R
S-
X9
[2]
MFZ.6F
X40
X29
X20
[1] Jumper to supply the MOVIMOT
®
drive with DC 24 V voltage for the fieldbus inter-
face (installed at the factory)
[2] Hybrid cable connection
22870857/EN – 12/2016