8
Service
Fault messages with parameterizable response
Operating Instructions – MOVIMOT
®
flexible
198
8.3
Fault messages with parameterizable response
Fault
Description
Index
no.
Possible fault response
Heat sink overtempera-
ture – prewarning
Here you can set the device re-
sponse when the prewarning
threshold for heat sink utilization is
exceeded (index 8336.1).
8622.2
•
No response
•
Warning
Positioning lag error
Here you can set the device re-
sponse to a lag error (lag error win-
dow exceeded, index 8509.4).
8622.3
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
Line phase failure
Here you can set the device re-
sponse to a line phase failure (val-
ues below threshold defined by the
user, index 8351.5).
8622.4
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
External fault
Here you can set the device re-
sponse to an external fault (e.g.
triggered by terminal or control
word).
8622.5
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
Fieldbus – timeout
Here one can set how the device is
to respond to a timeout on the
EtherCAT
®
/SBus
PLUS
(timeout period,
Index 8455.3).
8622.6
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
•
Warning with self-reset
•
Application stop (with out-
put stage inhibit) with self-
reset
•
Emergency stop (with out-
put stage inhibit) with self-
reset
•
Inhibit output stage with self
reset
29128668/EN – 12/2019
Содержание MOVIMOT flexible MMF3 C/DBC Series
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 429: ......
Страница 430: ......
Страница 431: ......