igus chainflex
The following table shows the core assignment of cables with the following part num-
bers:
Part numbers
28111001, 28111036
Assembly
Open cable end
Description
Prefabricated plug
connectors
2
1
5
4
3
Core
color/
Core
cross sec-
tion
Identi-
fication
Assembly
Signal
Contact
1)
–
Not pre-
fabricated
DC 24 V auxiliary output
24V_OUT
1
Black
0.75 mm
2
1
Not pre-
fabricated
F_STO_P2 connection
F_STO_P2
2
1)
–
Not pre-
fabricated
0V24 reference potential
for DC 24 V auxiliary output
0V24_OUT
3
Black
0.75 mm
2
2
Not pre-
fabricated
F_STO_P1 connection
F_STO_P1
4
Black
0.75 mm
2
3
Not pre-
fabricated
F_STO_M connection
F_STO_M
5
1) Do not connect these cores in the plug connector.