5
Electrical installation
Terminal assignment
Operating Instructions – MOVIMOT
®
advanced
49
Assignment
Terminal
No
.
Name
Marking
Function
X9
control termi-
nals
1
F_STO_P1
Yellow
Input STO+
2
F_STO_P1
Yellow
Input STO+
(to loop through)
3
0V24_OUT
–
0V24 reference potential
for DC 24 V output
4
24V_OUT
–
DC 24 V output
5
DI01
–
Digital input DI01
6
DI02
–
Digital input DI02
11 F_STO_M
Yellow
Input STO_ground
12 F_STO_M
Yellow
Input STO_ground
(to loop through)
13 24V_IN
–
DC 24 V supply
14 DOR-C
–
Relay output DO R, common contact
15 DI03
–
Digital input DI03
16 DI04
–
Digital input DI04
21 F_STO_P2
Yellow
Input STO+
22 F_STO_P2
Yellow
Input STO+
(to loop through)
23 0V24_IN
–
0V24 reference potential
for DC 24 V supply
24 DOR-NO
–
Relay output DO R, NO contact
25 0V24_OUT
–
0V24 reference potential
for DC 24 V output
26 24V_OUT
–
DC 24 V output
X31
engineering
interface
1
0V24_OUT
–
0V24 reference potential
for DC 24 V auxiliary output
2
CAN_L
–
CAN Low connection
3
CAN_H
–
CAN High connection
4
24V_OUT
–
DC 24 V auxiliary output
1) With the switch disconnector option, the line terminal X1 is assigned to the internal wiring.
25891936/EN – 05/2020