8
Service
Fault table
Operating Instructions – MOVIMOT
®
advanced
160
Subfault: 13.24
Description: Travel range exceeded
Response: Encoder 1 – latest fault
Cause
Measure
Current position mode (index 8381.10) does not
allow for larger travel range.
Check the travel range.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.25
Description: Error during encoder startup
Response: Output stage inhibit
Cause
Measure
Fatal error during encoder startup.
Switch the device off and on again.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.26
Description: Digital motor integration fault – critical
Response: Encoder 1 – latest critical fault
Cause
Measure
Encoder of "Digital motor integration" signaled a
component fault.
– Check interference sources.
– Replace encoder.
Subfault: 13.27
Description: Digital motor integration fault
Response: Encoder 1 – latest fault
Cause
Measure
Encoder of "Digital motor integration" signaled a
component fault.
– Check interference sources.
– Replace encoder.
Subfault: 13.28
Description: Digital motor integration warning
Response: Encoder – warning
Cause
Measure
Encoder of "Digital motor integration" signaled a
warning.
– Check interference sources.
25891936/EN – 05/2020