![SEW-Eurodrive MOVIGEAR DAC B Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343130.webp)
130
Operating Instructions – MOVIGEAR® DAC-B
8
Description of power section parameters
Parameters
Motor utilization
index 8323.0
The parameter indicates the motor utilization calculated using motor model and current.
• Unit: [%]
Motor temperature
index 9872.255
The parameter indicates the measured motor temperature.
• Unit: [°C]
Power section parameters \ display values \ unit status
Power section
status
index 9702.2
The parameter indicates the status of the power section:
• 0 = Not ready
• 1 = Ready, output stage inhibited
• 2 = Ready, output stage enabled
Drive status
index 9702.7
The parameter indicates the operating state of the power section:
• 0 = Inhibited
• 1 = Controller inhibit
• 2 = System error
• 3 = No enable
• 6 = Enabled
• 7 = Rapid stop
• 8 = Integrator stop
• 9 = Emergency stop
• 12 = Pos. mode
• 15 = Reference travel
Error code error
index 9702.5
The parameter indicates a pending error with error number in plain text.
Suberror code
error index
10071.1
The parameter provides detailed information on the error of an error group.
Error source
index 10404.5
The parameter indicates the error source of a pending error:
• 0 = No error
• 1 = Power section
• 2 = Command pcb
Operating hours
index 8328.0
The parameter indicates the total number of hours for which the inverter has been
connected to the mains or an external DC 24 V supply.
• Storage cycle every 15 min
• Unit: [h]
0
0
I
Содержание MOVIGEAR DAC B
Страница 2: ...SEW EURODRIVE Driving the world...
Страница 257: ......