5
Electrical Installation
Han-Modular®-ABOX "MTA...-H12.-...-00", "MTA...-H22.-...-00"
Operating Instructions – MOVIFIT
®
-FC
75
5.8.4
Pin assignment of motor (X8)
5.8.5
Pin assignment of braking resistor (X6)
Motor
Pin
X8
Han-Modular
®
Compact with Han
®
EE
module, socket insert, female
1
TF+_M1
2
13_M1
3
U_M1
4
W_M1
5
TF-_M1
6
14_M1
7
15_M1
8
V_M1
PE
PE_M1
TIP
SEW-EURODRIVE recommends using the shielded and pre-fabricated SEW hybrid
cables specifically designed for connecting MOVIFIT
®
and motor with Harting plug
connectors, see the section "Hybrid cables" (see page 92).
3
4
8
6
1
2
3
4
5
6
7
8
External braking resistor
Pin
X6
Han
®
Q5/0, socket insert, female
1
n.c.
2
n.c.
3
+R
4
n.c.
5
–R
PE
PE/housing
PE