5
Electrical Installation
Han-Modular®-ABOX "MTA...-H12.-...-00", "MTA...-H22.-...-00"
Operating Instructions – MOVIFIT
®
-FC
73
5.8
Han-Modular
®
-ABOX "MTA...-H12.-...-00", "MTA...-H22.-...-00"
5.8.1
Description
The following figure shows the Han-Modular
®
-ABOX for MOVIFIT
®
-FC depending on
the fieldbus interface:
936437515
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
M12 plug connector for I/Os
M23 plug connector (12-pin) for I/O extension box
SBus (CAN)
With PROFIBUS: PROFIBUS IN
With PR EtherNet/IP + Modbus/TCP: Ethernet port 1
With DeviceNet: Wired to X11 plug connector (micro-style connector)
With PROFIBUS: PROFIBUS OUT or terminating resistor
With PR EtherNet/IP + Modbus/TCP: Ethernet port 2
Diagnostics socket (RJ10) under the screw connection
Han-Modular
®
plug connector for connecting an external braking resistor
Han-Modular
®
plug connector for connecting motor 2 (MOVIFIT
®
-SC only)
Han-Modular
®
plug connector for connecting motor 1
Han-Modular
®
plug connector for power connection (power distribution with T adapter)
PE connection
M12 plug connector for optional I/Os
[1]
[2]
[4]
[3]
[5]
[12]
[9]
[10]
[11]
[6]
[7]
[8]
X14
X11
X12
X19
X50
X21
X22
X23
X24
X41
X42
X43
X44
X25
X26
X27
X28
PROFINET
Ethernet/IP
MTA11A-503-H22
3
-...-00
DeviceNet
MTA11A-503-H12
2
-...-00
PROFIBUS
MTA11A-503-H12
1
-...-00
X1
X7
X8
X9
[4]
X14
X11
X11
X12
X19
X14
X19
[4]
[5]
NOTICE
According to IEC PAS 61076-3-117, push-pull RJ45 sockets may only be used with the
appropriate push-pull RJ45 mating connector. Commercially available RJ45 patch
cables without push-pull connector housings do not lock into the connectors. Such
cables can damage the sockets and are, therefore, not suitable.