5
Electrical Installation
Hybrid ABOX "MTA...-S62.-...-00"
Operating Instructions – MOVIFIT
®
-FC
69
5.7
Hybrid ABOX "MTA...-S62.-...-00"
5.7.1
Description
The following figure shows the hybrid ABOX with M12 plug connectors for connecting
I/Os and push-pull RJ45 plug connector for Ethernet connection:
Closing plug, optional
TIP
• The hybrid ABOX is based on the standard ABOX "MTA...-S02.-...-00". Therefore,
the following describes only the additional plug connectors in comparison with the
standard ABOX.
• For a description of the terminals, refer to section "Standard ABOX "MTA...-S02.-
...00"" (see page 43).
• Customers cannot use terminal strips X25, X30, or X31 because the described plug
connectors are assigned to them.
915673995
[1]
[2]
[3]
[4]
[5]
Maintenance switch (integrated as standard in connection with MOVIFIT
®
-MC)
PE connection
M12 plug connector for I/Os
Diagnostics socket (RJ10) under the screw connection
Push-pull RJ45 plug connector for Ethernet connection
[2]
[1]
[3]
[4]
[5]
X21
X22
X23
X24
X25
X26
X27
X28
X11
X12
NOTICE
According to IEC PAS 61076-3-117, push-pull RJ45 sockets may only be used with the
appropriate push-pull RJ45 mating connector. Commercially available RJ45 patch
cables without push-pull connector housings do not lock into the connectors. Such
cables can damage the sockets and are, therefore, not suitable.
Type
Figure
Contents
Part number
Ethernet closing plug
for push-pull RJ45 socket
10 pieces
1822 370 2
30 pieces
1822 371 0