5
Electrical Installation
Standard ABOX "MTA...-S02.-...-00"
Operating Instructions – MOVIFIT
®
-FC
51
812534411
Motor connection terminal (connection via hybrid cable)
No.
Name
Function of motor with SEW standard
brake
Working motor with 2-wire,
constant DC brake
1)
X8
1
PE
PE connection motor
2
U
Output motor phase U
3
V
Output motor phase V
4
W
Output motor phase W
5
15
Connection for SEW brake terminal 15 (blue)
DC brake connection (+)
6
14
Connection for SEW brake terminal 14 (white) No function
7
13
Connection for SEW brake terminal 13 (red)
DC brake connection (–)
X81
1
TF+
Connection for temperature sensor TF/TH (+) motor
2
TF-
Connection for temperature sensor TF/TH (–) motor
3
DB00
Binary output "Brake released" = factory setting (control signal 24 V)
4
0V24_C
0V24 reference potential for brake output
X9
1
PE
PE connection
2
-
Reserved
3
-
Reserved
4
-
Reserved
5
-R
Braking resistor connection "–R"
6
-
Reserved
7
+R
Braking resistor connection "+R"
X91
1-4
-
Reserved
1) Before starting up a MOVIFIT
®
-FC drive that uses a constant DC brake, you must connect an additional, external braking resistor to
the MOVIFIT
®
-FC inverter. The braking resistor is used to dissipate the regenerative energy.
DANGER
If you use binary output DB00 to control the brake, do not change the parameters of
the binary output functions.
Severe or fatal injuries
• Before using the binary output for controlling the brake, check the parameter
settings.
1
11
1 12
1213
1314
1415
15 16
16
2 3 4 5 6
17
1718
18
7 8
X29
1 2 3 4
X91
S3
1
11 12 13 14 15 16
2 3 4 5 6
X20
1 2 3 4
11 12 13 14
X1
11
1 2 3 4 5 6 7 8
12 13 14 1516 17 18
31 32 33 34 35 36 37 38
21 22
11
1 2 3 4 5
12 13 14 15
31 32 33 34 35
21 22 23 24 25
11
1 2 3 4 5
12 13 14 15
2324 25 26 27 28
X45
X25
X35
X50
5
6
7
5
1
1 2 3 4
2
3
4
1
2
3
4
6
7
X81
X8
X9