7
Operation
Status LEDs for MOVIFIT®-FC
Operating Instructions – MOVIFIT
®
-FC
123
7.1.7
Option-specific LEDs
PROFIsafe option
S11
This section describes the option-specific LEDs for PROFIsafe option S11. In the
following figure, these LEDs are shown as dark. In the sample figure, the PROFIBUS
versions are shown in the "Technology" or "System" function level:
LEDs "FDI." and
"FDO."
The following table shows the statuses of the "FDI." and "FDO." LEDs:
DANGER
If you are using PROFIsafe option S11, you must observe the SEW publication "Safe
Disconnection for MOVIFIT
®
".
Severe or fatal injuries
• Note additional diagnostic and operating notes when using PROFIsafe option S11
in the SEW publication "Safe Disconnection for MOVIFIT
®
".
836130059
DI03
DI01DI02
DI00
DI04DI05DI06DI07
DI08DI09DI10DI1
1
DI12/DO00
DI13/DO01
DI14/DO0
2
DI15/DO03SF/USR
BUS-F
24V
-C
24V
-S
RUN
F-ST
ATE
ST
O
FDI00FDI01FDI02FDI03FDO00FDO01
MOVIFIT
®
RUN PS
LED
Status Meaning
FDI0
Yellow
HIGH level on input F-DI0
Off
LOW level on input F-DI0 or open
FDI1
Yellow
HIGH level on input F-DI1
Off
LOW level on input F-DI1 or open
FDI2
Yellow
HIGH level on input F-DI2
Off
LOW level on input F-DI2 or open
FDI3
Yellow
HIGH level on input F-DI3
Off
LOW level on input F-DI3 or open
FDO0
Yellow
Output F-DO0 active
Off
Output F-DO0 inactive (switched off)
FDO1
Yellow
Output F-DO1 active
Off
Output F-DO1 inactive (switched off)
Содержание MOVIFIT-FC