7
Operation
Status LEDs for MOVIFIT®-FC
Operating Instructions – MOVIFIT
®
-FC
111
7
Operation
7.1
Status LEDs for MOVIFIT
®
-FC
7.1.1
General LEDs
This section describes the fieldbus- and option-independent LEDs. These LEDs are
shown as dark in the figures. The LEDs that are shown to be white differ depending on
which fieldbus version is used. They are described in the following sections. The fol-
lowing figures show examples of the PROFIBUS variants:
LEDs "DI.." and
"DO.."
The following table shows the statuses of the LEDs "DI.." and "DO..":
"24V-C" and
"24V-S" LEDs
The following table shows the statuses of the "24V-C" and "24V-S" LEDs:
Function level "Classic" with PROFIBUS or DeviceNet
835907723
Function level "Technology" or "System" with PROFIBUS, DeviceNet, or PROFINET
Function level "Classic" with PROFINET
835912971
DI02
DI01
DI00
DI03
DI04
DI06/DO0
0
DI07/DO0
1
SF/USR
BUS-F
24V
-C
24V
-S
RUN
DI05
RUN PS
MOVIFIT
®
DI03
DI01DI02
DI00
DI04DI05DI06DI07
DI08DI09DI10DI1
1
DI12/DO00
DI13/DO0
1
DI14/DO0
2
DI15/DO03SF/USR
BUS-F
24V
-C
24V
-S
RUN
RUN PS
MOVIFIT
®
LED
Status
Meaning
DI00 to
DI15
Yellow
Input signal present at binary input DI.. present
Off
Input signal at binary input DI.. open or "0".
DO00 to
DO03
Yellow
Switched DO.. output.
Off
DO.. output logical "0"
LED
Status
Meaning
Remedy
24V-C
Green
24V_C continuous voltage is present.
-
Off
24V_C continuous voltage is missing.
Check 24V_C voltage supply.
24V-S
Green
24V_S actuator voltage is present.
-
Off
24V_S actuator voltage is missing.
Check 24V_S voltage supply.