5
Electrical installation
Standard ABOX MTA...-S02.-...-00
Operating Instructions – MOVIFIT
®
FC
64
Connecting the hybrid cables
• SEW
‑
EURODRIVE recommends using the shielded and prefabricated SEW hybrid
cables specifically designed for connecting MOVIFIT
®
to the motor.
See chapter "Electrical Installation" > "Hybrid cables".
• The outer shield of the hybrid cable must be attached to the housing of the unit us-
ing a suitable EMC cable gland.
• The inner shield of the hybrid cable must be connected via a shield plate in the
MOVIFIT
®
ABOX as follows:
ABOX
9007200067175563
INFORMATION
• In contrast to the standard ABOX, the hybrid ABOXes MTA...-I..-...-00 and MTA...-
G..-...-00 have no shield plates. Here, the cable shields must be connected via
EMC cable glands.
21316996/EN – 12/2014