6
Startup
Description of the DIP switches
Operating Instructions – MOVIFIT
®
FC
137
DIP switch S10/6
Lifting application
• DIP switch S10/6 = ON: You must make this setting when MOVIFIT
®
is to be used
in a lifting application. The control mode is VFC mode for the hoist and 4-pole SEW
motors.
• DIP switch S10/6 = OFF: The operating mode is selected according to DIP switch
S10/2.
6.3.6
DIP switch S11
IP parameters for PROFINET IO, EtherNet/IP™ and Modbus/TCP
You can set the IP parameters for PROFINET IO, EtherNet/IP™ and Modbus/TCP at
DIP switches S11/1 – S11/2.
S11
D
H
C
P
D
EF
I
P
re
s.
(O
F
F
)
re
s.
(O
F
F
)
ON
1 2 3 4
9007200422438795
S11/1
"DHCP"
S11/2
"DEF IP"
Status
ON
ON
This combination of settings is not permitted.
ON
OFF
The MOVIFIT
®
unit awaits the IP parameter being assigned by
a DHCP server.
OFF
ON
The IP parameters are set to the following default values when
the DC 24 V voltage is switched on:
IP address:
192.168.10.4
Subnet mask:
255.255.255.0
Default gateway:
1.0.0.0 with EtherNet/IP™
DHCP / Startup Configuration:
Saved IP parameters (DHCP
is deactivated)
OFF
OFF
The IP parameters set in the parameter tree are used. On deliv-
ery, the above-mentioned default values are set.
21316996/EN – 12/2014