9
Technical data
MOVIFIT® compact inverter
Operating Instructions – MOVIFIT
®
compact
94
9.2
MOVIFIT
®
compact inverter
MOVIFIT®
compact
inverter
MOVIFIT
®
compact type
MBF07B-..
MBF11B-..
MBF15B-..
Apparent output power with
V
line
= AC 380 – 500 V
S
N
1.8 kVA
2.2 kVA
2.8 kVA
Connection voltages
U
Mains
3 x AC 380 V –10% – AC 500 V ±10%
Line frequency
f
Mains
50 – 60 Hz ±5%
Nominal line current
(with V
line
= AC 400 V)
I
Mains
AC 1.5 A
AC 2.2 A
AC 2.8 A
Output voltage
V
O
0 – V
line
(output is short-circuit-proof)
Output frequency
f
A
2 – 200 Hz
Operating point
3 x AC 400 V at 50 Hz
Nominal output current
I
N
AC 1.7 A
AC 2.5 A
AC 3.4 A
Motor power S1
P
Mot
0.09 –
0.75 kW
0.12 – 1.0 HP
0.09 –
1.1 kW
0.12 – 1.5 HP
0.09 –
1.5 kW
0.12 – 2.0 HP
PWM frequency
4 (factory setting), 16 kHz
Efficiency
> 96%
Current limiting
I
max
150%, 60 s
130%, 60 s
Maximum motor cable
length
3 m unshielded
Permitted motors
Asynchronous motors
Interference immunity
Complies with EN 61800-3
Interference emission
•
Fulfills category C3 in accordance with
EN 61800-3
(without EMC filter)
•
Fulfills category C2 in accordance with
EN 61800-3
(EMC filter MNF21A-MB or MNF21A-MB/
CA11 installed)
Ambient temperature
ϑ
A
-25 °C to +40 °C
P
N
reduction: by 3% per K up to max. 60 °C
Climate class
EN 60721-3-3, class 3K3
Storage temperature
1)
-25 °C to +75 °C
(EN 60721-3-3, class 3K3)
Permissible vibration and
impact load
3M7 in accordance with EN 50178
Degree of protection
IP55 (MOVIFIT
®
compact housing closed and all
plug connections sealed off).
Degree of pollution
2
Duty type
S1 (EN 60149-1-1 and 1-3)
Type of cooling
(DIN 41751)
Natural cooling
22527060/EN – 08/2017