6
Startup
Requirements
Operating Instructions – MOVIFIT
®
compact
44
WARNING
Danger of burns due to hot surfaces of the device (e.g. the heat sink).
Serious injuries.
•
Do not touch the device until it has cooled down sufficiently.
NOTICE
Danger due to arcing.
Damage to electrical components.
•
Do not unplug the power connectors during operation. Do not plug in the power
connectors during operation.
•
Never remove the EBOX during operation.
INFORMATION
During startup and parameterization, written parameters are stored in non-volatile
memory (e.g. in an EEPROM). However, memory modules only allow a certain num-
ber of write cycles.
•
For this reason, ensure that write accesses to parameters do not take place cyc-
lically.
6.2
Requirements
The following conditions apply to startup:
•
The MOVIFIT
®
compact device must be mechanically and electrically installed in
accordance with regulations.
•
Appropriate safety measures prevent the drives from starting up unintentionally.
•
Appropriate safety measures must be taken to prevent personal injury or damage
to machine.
The following hardware must be present in order to start up and parameterize the
MOVIFIT
®
compact device:
•
MBBG11A operator panel, see chapter "Connecting the MBBG11A operator
panel"
•
or PC/laptop, see chapter "Connecting a PC/laptop"
The following software must be installed on the PC or laptop in order to start up and
parameterize the MOVIFIT
®
compact inverter:
•
MOVITOOLS
®
MotionStudio, version 6.2 or above
22527060/EN – 08/2017