4
Project planning for the PROFIBUS DP master
Project Planning and Startup
4. Enter the I/O or peripheral addresses for the configured data widths in the "I Address"
and "Q Address" columns.
DP configuration
To enable the DHP11B control card to support the type and number of the input and out-
put data used for transmission, the DP master must transmit the corresponding DP con-
figuration to the DHP11B control card. The configuration telegram consists of the DP
configurations for slots 1 to 3.
The following options are available:
•
Controlling the DHP11B control card via process data
•
Reading or writing parameters using the parameter channel
•
Using definable data exchange between the DHP11B control card and higher-level
controller (
→
Section "Universal DP configuration" for slot 3,page 33).
20079AXX
Figure 14: Project planning in HW Config of SIMATIC STEP7; Finished configuration example with
cyclical MOVILINK parameter channel and 10 PD