6
Service
Fault messages and list of faults
Compact Operating Instructions – MOVIDRIVE
®
MDX60B/61B
50
Fault
Subfault
Code Designation Response
(P)
Code
Designation
Possible cause
Measure
109
DCS alarm
Display fault 146
Voltage supply of encoder
faulty (E3405 = encoder 1
and E3406 = encoder 2).
The voltage supply of the en-
coder is not within the defined
range (min. DC 20 V / max.
DC 29 V).
• Overload in the supply
voltage of the encoder; in-
ternal polyswitch fuse has
tripped.
• Check supply voltage of
DCS..B option.
147
150
Difference level RS485
driver. Fault Faulty "B" or
"Cycle" signal.
• No encoder connection.
• Incorrect encoder type con-
nected.
• Check encoder connection.
• Check encoder cabling.
151
152
Difference level RS485
driver. Fault Faulty "A" or
"DATA" signal.
• No encoder connection.
• Incorrect encoder type con-
nected.
• Check encoder connection.
• Check encoder cabling.
153
158
Plausibility fault SIN/COS
encoder connection.
Incorrect encoder type connec-
ted.
Check encoder connection
and cabling.
159
164
Plausibility fault - SSI en-
coder connection (master
mode).
Connected encoder type does
not correspond to the configur-
ation.
• Check encoder connection
and cabling.
• Check encoder.
165
166
Plausibility fault SSI en-
coder connection (slave
mode).
Connected encoder type does
not correspond to the configur-
ation
• Check encoder connection
and cabling.
• Check encoder.
167
186
EMU1 monitoring fault.
Faulty monitoring of the ex-
ternal shutdown channel.
• Check hardware connec-
tions.
• Pick-up or release time too
short.
• Check switch contacts.
187
188
EMU2 monitoring fault.
Faulty monitoring of the ex-
ternal shutdown channel.
• Check hardware connec-
tions.
• Pick-up or release time too
short.
• Check switch contacts.
189
109
DCS alarm
Display fault 190
Plausibility fault position
changeover.
Position changeover during
ZSC, JSS or DMC is perman-
ently activated.
• Check ZSC (SOS) activa-
tion.
• Check JSS (SDI) activation.
• Check DMC (SDI) activa-
tion only for monitoring the
position.
191
192
SSI encoder fault.
Encoder step SSI value within
one cycle is too large.
• Check encoder configura-
tion.
• Check encoder cabling.
193
194
SSI encoder fault.
Plausibility fault for position ad-
justment.
• Check encoder configura-
tion.
• Check encoder cabling.
195
196
Plausibility fault of incre-
mental encoder tracks.
• Different counting signals on
A/B encoder tracks.
• Defective component at
RS485 interface.
• Encoder operates outside
tolerances of encoder inter-
face.
• Check encoder configura-
tion.
• Check encoder cabling.
• Check encoder signal
levels.
• Check maximum counting
frequency of incremental
encoder.
197
198
Plausibility fault analog/di-
gital comparison at
Schmitt trigger output –
encoder input X84.
• Connected encoder type
does not correspond to the
configuration.
• Faulty encoder signals
• Hardware defective
• Check configuration.
• Check connected encoder.
• Replace DCS..B option.
• Send faulty DCS..B option
with fault number to
SEW‑EURODRIVE for fault
diagnostics.
199
200
Plausibility fault analog/di-
gital comparison at
Schmitt trigger output –
encoder input X85.
• Connected encoder type
does not correspond to the
configuration.
• Faulty encoder signals
• Hardware defective
• Check configuration.
• Check connected encoder.
• Replace DCS..B option.
• Send faulty DCS..B option
with fault number to
SEW‑EURODRIVE for fault
diagnostics.