Automatic mode
Operation
6.6
Automatic mode
Selecting "Automatic" mode means a sequencer is run through and the following
functions are processed:
Initialization is repeated in the following cases:
• Selecting an operating mode
• Positive edge of Start
• Reset of the axes following an encoder error
• Drives change to "A" state (technology function)
Automatic mode is initialized
•
The axis system is adjusted to the calculated common
"adjust position".
•
The virtual encoder position is referenced to the adjust
position.
•
"Synchronous operation" mode is activated
Cyclical program section:
Processing the virtual encoder
•
Cyclical processing of the virtual setpoints
•
Cyclical correction/slip compensation between the virtual
master encoder position and the read-in external encoder
position in synchronous operation.
•
Monitoring of lag error, encoder error, and inverter error