Manual – MOVI-PLC® Application Solution "SyncCrane"
49
5
Parameters/H variables of the MOVI-PLC®
Startup
5.4
Parameters/H variables of the MOVI-PLC
®
The wizard for startup, operation, and diagnostics of the application module is imple-
mented in the SEW-EURODRIVE ApplicationBuilder. The ApplicationBuilder uses the
remanent "H variables" of the MOVI-PLC
®
for:
• saving the startup data
• intermediate saving of diagnostics variables
• mapping process data communication between bus master and MOVI-PLC
®
.
The following table shows the data buffer MOVI-PLC
®
H variables 0 ... 1450.
Segment
H variables
Saved data
1st
segment
H000 SwitchMonitor H
H0001 PO1
. . .
H0099 PO99
H0101 PI1
. . .
H0199 PI99
Process input data
words and process
output data words
The setpoint source can
be switched from fieldbus
to RS-485 via the variable
H0000. This allows for
controlling the application
module by means of the
control mode of the Appli-
cationBuilder or a DOP
operator terminal.
2nd
segment
H0200 Axis status bits (e.g. InGear)
. . .
H0218
Status bits of the indi-
vidual axes
–
3rd
segment
H0220 Axis 1
. . . Diagnostics
H0249 e.g. InverterState
Diagnostics variables
of individual axes
•
Actual positions
•
Currents
•
Operating states, etc.
H0220 Axis 2
. . . Diagnostics
H0279 e.g. InverterState
. . .
. . .
. . .
H0520 Axis 12
. . . Diagnostics
H0549 e.g. InverterState
4th
segment
H0600 VirtualAxis
. . . Diagnostics
H0629 e.g. ActualSpeed
Diagnostics variables
of the virtual axis
•
Actual positions
•
Actual speed, etc.
H0630 Reserved
. . .
H0739
5th
segment
H0740 AppBuilder
. . . Startup Rand Single AxisScaling
H1450
Startup data of the
ApplicationBuilder
•
Scaling factors
•
Limits, etc.
0