18
Manual – MOVI-PLC® Application Solution "SyncCrane"
3
Functional description
Project Planning
Automatic mode
• Automatic mode is used as motion control based on the technology function "Internal
Synchronous Operation" (ISYNC) and is controlled in the inverter. Once automatic
mode is selected, the axis system is adjusted to a common "adjust position" in
positioning mode and the axis system is synchronized accordingly. The axis system
can then be moved using the virtual master encoder.
• Master value specification via virtual encoder is made either in jog or positioning
mode.
• The startup wizard lets you specifiy a jerk time for the virtual encoder.
• Position deviations between virtual encoder position and external synchronous
encoder are compensated cyclically during ongoing movement. This is to adjust, for
example, varying wear on the drive wheels without limiting positioning accuracy.
Emergency mode
• The drive is moved clockwise or counterclockwise using two bits for direction
selection.
• Velocity and ramp can be specified via fieldbus as required.