PROFIdrive return
codes for DP-V1
The following table shows the coding of the
error number
in the PROFIdrive DP-V1
parameter response according to PROFIdrive profile V3.1. This table applies if you use
the PROFIdrive services
Request Parameter
or
Change Parameter
.
Error no.
Meaning
Used at
Supplem. Info.
0x00
Impermissible parameter
number
Access to unavailable parameter
0
0x01
Parameter value cannot be
changed
Change access to a parameter value
that cannot be changed
Subindex
0x02
Low or high limit exceeded
Change access with value outside the
value limits
Subindex
0x03
Faulty subindex
Access to unavailable subindex
Subindex
0x04
No array
Access with subindex to non-indexed
parameter
0
0x05
Incorrect data type
Change access with value that does not
match the data type of the parameter
0
0x06
Setting not permitted (can
only be reset)
Change access with value unequal to 0
where this is not permitted
Subindex
0x07
Description element cannot
be changed
Change access to a description element
that cannot be changed
Subindex
0x08
Reserved
(PROFIdrive Profile V2: PPO-Write
requested in IR not available)
–
0x09
No description data avail-
able
Access to unavailable description
(parameter value is available)
0
0x0A
Reserved
(PROFIdrive Profile V2: Access group
wrong)
–
0x0B
No operation priority
Change access without rights to change
parameters
0
0x0C
Reserved
(PROFIdrive Profile V2: Wrong pass-
word)
–
0x0D
Reserved
(PROFIdrive Profile V2: Text cannot be
read in cyclic data transfer)
–
0x0E
Reserved
(PROFIdrive Profile V2: Name cannot be
read in cyclic data transfer)
–
0x0F
No text array available
Access to text array that is not available
(parameter value is available)
0
0x10
Reserved
(PROFIdrive Profile V2: No PPO-Write )
–
0x11
Request cannot be
executed because of oper-
ating state
Access is temporarily not possible for
reasons that are not specified in detail
0
0x12
Reserved
(PROFIdrive Profile V2: Other error)
0x13
Reserved
(PROFIdrive Profile V2: Data cannot be
read in cyclic interchange)
0x14
Value impermissible
Change access with a value that is within
the value limits but is not permissible for
other long-term reasons (parameter with
defined single values)
Subindex
0x15
Response too long
The length of the current response
exceeds the maximum transmittable
length
0
0x16
Parameter address imper-
missible
Illegal value or value which is not
supported for the attribute, number of
elements, parameter number or
subindex or a combination
0
0x17
Illegal format
Write request: Illegal format or format of
the parameter data which is not
supported
0