5
Electrical installation
Assignment of the optional plug connectors
Operating Instructions – MOVIMOT
®
flexible
95
Connection cables
INFORMATION
Use only shielded cables for this connection and only suitable plug connectors that
connect the shield with the device in an HF-capable manner.
The following table provides an overview of the cables available for this connection:
Connection cables
Conformity/
part num-
ber
Cable type
Length/in-
stallation
type
Cable
cross sec-
tion/operat-
ing voltage
CE/UL:
28110935
HELUKABEL
®
LiYCY
Variable
3 ×
0.75 mm
2
/
DC 60 V
M12, 5‑pin,
A‑coded,
female
M12, 5‑pin,
A‑coded, male
CE/UL:
28110943
HELUKABEL
®
LiYCY
Variable
3 ×
0.75 mm
2
/
DC 60 V
Open
M12, 5‑pin,
A‑coded, male
CE/UL:
28110951
HELUKABEL
®
LiYCY
Variable
3 ×
0.75 mm
2
/
DC 60 V
M12, 5‑pin,
A‑coded,
female
M12, 5‑pin,
A‑coded, male
CE/UL:
28110978
HELUKABEL
®
LiYCY
Variable
3 ×
0.75 mm
2
/
DC 60 V
Open
M12, 5‑pin,
A‑coded, male
29129451/EN – 12/2019