9
Inspection and maintenance
Determining the operating hours
Operating Instructions – MOVIMOT
®
flexible
263
9
Inspection and maintenance
9.1
Determining the operating hours
9.1.1
About MOVISUITE
®
The device allows for reading the operating hours performed in order to assist with in-
spection and maintenance work.
To determine the operating hours performed, proceed as follows:
1. In MOVISUITE
®
, open the parameter tree of the device.
2. In the parameter tree [4], select the "Status" node.
ð
The
operating hours
performed can be found in the "kWh and operating
hours" [3] group.
27021619739284235
[1]
Display of operating and drive running hours performed
[2]
Display of active power and active energy
9.2
Inspection and maintenance intervals
The following table shows the inspection and replacement intervals for the device:
Time interval
What to do?
Who is permitted to
perform the work?
When the cover/elec-
tronics cover is opened
after an operating
period of ≥ 6 months
When the cover/electronics cover
is opened after an operating
period of ≥ 6 months, the gasket
between the connection box and
the cover/electronics cover must
always be replaced.
The 6-month period can be
shortened by harsh ambient/oper-
ating conditions, e.g. cleaning with
aggressive chemicals or frequent
temperature variations.
Specialists at cus-
tomer site
29129451/EN – 12/2019