8
Service
Switch-off responses
Operating Instructions – MOVIMOT
®
flexible
191
8.2
Switch-off responses
Fault response
Description
No response
The inverter ignores the event.
Warning with self‑reset
The inverter sends a warning message with self-reset.
Warning
The inverter issues a warning message.
Application stop (with output
stage inhibit)
The inverter stops with the deceleration set for the application limit.
For n=0: Brake "applied" and output stage "off".
Application stop (with output
stage inhibit) with self‑reset
Emergency stop (with output
stage inhibit)
The inverter stops with the set emergency stop deceleration.
Emergency stop (with output
stage inhibit) with self-reset
Inhibit output stage with self‑re-
set
The output stage is deactivated and the brake is applied.
Inhibit output stage
Self-reset means: Eliminating the cause of the fault acknowledges the fault. The in-
verter automatically resumes the operation performed before the fault. The drive re-
starts automatically.
29129451/EN – 12/2019