
15
Technical data
Technical data for field distributors
Manual – EtherCAT
®
Interfaces, Field Distributors
125
15.4.4
MF../MM../Z.8. field distributors with operating point 400 V/50 Hz
MF../MM..-503-00/Z.8.
MOVIMOT
®
inverter
MM
03D
MM
05D
MM
07D
MM
11D
MM
15D
MM
22D
MM
30D
MM
40D
Size
1
2
2L
Connection voltages
V
line
AC 3 x 380 V -10% – AC 500 V +10%
Line frequency
f
line
50 – 60 Hz
Max. permitted total cur-
rent X1
(X1 terminal)
I
max
32 A (according to UL max. 30 A)
Motor power S1
P
Mot
0.37 kW
0.5 HP
0.55 kW
0.75 HP
0.75 kW
1.0 HP
1.1 kW
1.5 HP
1.5 kW
2.0 HP
2.2 kW
3.0 HP
3.0 kW
4.0 HP
4.0 kW
5.4 HP
Nominal line current
I
line
AC
1.3 A
AC
1.6 A
AC
1.9 A
AC
2.4 A
AC
3.5 A
AC
5.0 A
AC
6.7 A
AC
7.3 A
Nominal output current
I
N
AC
1.6 A
AC
2.0 A
AC
2.5 A
AC
3.2 A
AC
4.0 A
AC
5.5 A
AC
7.3 A
AC
8.7 A
Output voltage
V
O
0 – V
line
Max. permitted total cur-
rent X21
(X21 terminals)
32 A
Max. permitted total cur-
rent X20
(X20 terminals)
12 A
Maintenance switch
Load disconnector
Type: ABB OT16ET3HS3ST1
Switching: black/red, triple lock
Ambient temperature
-25 °C – 40 ˚C (P
N
reduction: 3% I
N
per K to max. 55 °C)
Storage temperature
-25 °C – 85 °C
Degree of protection
IP65 (fieldbus interface, power supply connection cover, MOVIMOT
®
in-
verter and motor connection cable attached and fastened, all plug con-
nections sealed)
Interface
PROFIBUS, PROFINET IO, EtherNet/IP™, EtherCAT
®
, DeviceNet™
Permitted motor cable
length
15 m (with SEW‑EURODRIVE hybrid cable, type A)
Mass
Approx. 5.2 kg
Approx. 6.7 kg
25809148/EN – 01/2019