5
Electrical installation
Terminal assignment
Operating Instructions – MOVI-C
®
FIELD CONTROLLER standard/advanced
45
5.5
Terminal assignment
The following figure shows the terminal assignment in the connection box of the
device:
1
2
3
11 12 13
1
2
3
11 12 13
X1_a
PE
X9
X1_b
1 2 3 4
11 12 13 14
21 22 23 24
1
2
3
4
11
12
13
14
21
22
23
24
5
15
25
5
15
25
6
16
26
5
16
26
7
17
27
5
17
27
PE
32854784011
Assignment
Terminal
No.
Name
Marking
Function
X1_a
line terminals
1
L1
Brown
Line connection, phase L1 – IN
2
L2
Black
Line connection, phase L2 – IN
3
L3
Gray
Line connection, phase L3 – IN
11
L1
Brown
Line connection, phase L1 – OUT
12
L2
Black
Line connection, phase L2 – OUT
13
L3
Gray
Line connection, phase L3 – OUT
X1_b
line terminals
(in connection
with switch disconnector
disconnectable)
1
L1
Brown
Line connection of drive units,
phase L1
2
L2
Black
Line connection of drive units,
phase L2
3
L3
Gray
Line connection of drive units,
phase L3
11
L1
Brown
Line connection of drive units,
phase L1
12
L2
Black
Line connection of drive units,
phase L2
13
L3
Gray
Line connection of drive units,
phase L3
y
–
PE
–
PE connection