10
Technical data and dimension sheets
Technical data
Operating Instructions – MOVI-C
®
FIELD CONTROLLER standard/advanced
141
10.3.5
Technical data for PROFINET IO interface
PROFINET IO
Manufacturer ID
010A
hex
Device ID
15
dec
Connection technology
M12 plug connector
Baud rate
100 MBd (full duplex)
Application protocols
PROFINET IO, HTTP, SNMP, SEW Application Services
Port numbers used
80, 161, 310, PROFINET DCE/RPC Ports (dynamic via End Point Mapper)
Conformance class
C
Real time class
RT (Real Time), IRT (Isochronous Real Time)
Netload class
3
Topology detection
Yes (LLDP)
Auto addressing
Yes (LLDP, DCP)
I&M
1 – 5
Media redundancy
MRP
Shared device
Yes
Ethernet switch
2 ports, integrated
Technology
Cut Through, Store and Forward
Latency period
Cut Through
5.5 μs
Latency period
Store and Forward
Depending on package size
Application profiles
PROFIsafe, PROFIenergy
Permitted cable types
Category 5 and higher, class D according to IEC 11801
Maximum cable length
(from switch to switch)
100 m
GSD file name
GSDML-Vx.yz-SEW-MOVI-C-CONTROLLER-FHX25-FHX45-jjjjmmdd-
hhmmss
Bitmap file name
GSDML-010A-000F-SEW-MOVI-C-FHXx5.bmp
26872137/EN – 12/2021