6
Startup
Shutting down gear units
Assembly and Operating Instructions – M1..N Series Single-Stage Helical Gear Units
76
6.6
Shutting down gear units
WARNING
Risk of crushing if the drive starts up unintentionally.
Severe or fatal injuries.
•
Work on the gear unit only when the machine is not in use. Secure the drive unit
against unintentional power-up. Attach an information sign near the ON switch to
warn that the gear unit is being worked on.
If the gear unit is not operated for an extended period of time, take it into operation at
regular intervals of approx. 2 – 3 weeks.
If the gear unit is not operated for a period
longer than 6 months
, additional corro-
sion protection is required:
•
Corrosion protection for the inside of gear units with splash lubrication or
bath lubrication:
Fill the gear unit up to the breather plug with the oil grade specified on the name-
plate.
•
Corrosion protection for the inside of gear units with oil pressure lubrica-
tion:
In this case contact SEW‑EURODRIVE.
•
Exterior corrosion protection:
Apply a wax-based protective coating to shaft ends and unpainted surfaces as ex-
ternal corrosion protection. Grease the sealing lips of the oil seal to protect them
from preservative agents.
INFORMATION
Observe the notes in chapter "Startup" before restarting the gear unit.