![SEW-Eurodrive IPOS plus Скачать руководство пользователя страница 321](http://html1.mh-extra.com/html/sew-eurodrive/ipos-plus/ipos-plus_manual_1250042321.webp)
Manual – IPOSplus®
321
23
Communication commands
Assembler – Commands
The length of a variable corresponds to 4 bytes. This means for a data length of 8 bytes,
two consecutive variables are transmitted.
Receiver settings
23.5.5 SCOMON
S
ystem Bus
Com
munication
On
This command triggers the reception of data or the cyclical transmission of previously
defined data objects.
The SCOM command initializes the data objects with the arguments RECEIVE (receiv-
ing data) or TRANSMIT CYCLIC (sending data cyclically).
In MOVIDRIVE
®
B, the command has been replaced by SCOMST. However, due to
downward compatibility, it can still be used with MOVIDRIVE
®
B.
514591883
H0 Objectno. 1025 = user-defined
H1 Len
8
= Variable length 8 bytes
H2 D-Pointer 5
= Data pointer value at H5
H5
11111 = sent value
INFORMATION
The synchronization procedure (sync ID) has been modified from MOVIDRIVE A. In
contrast to MOVIDRIVE
®
A, for MOVIDRIVE
®
B you must ensure that in the IPOS
plus®
program of the master drive the actual position is initialized
first
and
then
the sync ob-
ject with SCOM().
INFORMATION
This command only activates SBus 1, not SBus 2
• Preferably use the SCOMSTATE command.