Manual – IPOSplus®
17
Standard functions
Compiler – Functions
Example
main()
{
_Memorize( MEM_STDATA ); // Save variables H0 ... H127 to EEPROM
}
17.3.14 _MoviLink
Syntax
_MoviLink ( H )
Description
The MOVLNK command allows extensive changes to be made to the inverter parame-
ters and any other units which may be connected via the system bus or the RS-485. To
ensure the safety of people and systems, take particular care when changing the in-
verter parameters. In all cases, higher-level safety precautions must be able to intervene
to counteract any possible programming errors.
When the command is called, MOVLNK reads and writes process data, variables or pa-
rameters from one unit to another once, or reads or writes variables or parameters within
a unit once.
The parameters are read/written using index addressing. For the corresponding index
number, refer to the system manual and the parameter list. You can also display the
index numbers in MOVITOOLS
®
MotionStudio by placing the mouse on the edit box or
display field of the respective parameter (tooltip).
An SBus or RS-485 interface can be used for communication between 2 units.
MOVILINK can be used in a unit, for example, to save the variable of a quantity counter
protected against power outage without using the MEM command to save the entire
power-outage proof range. Process data cannot be exchanged within one unit using the
MOVILINK command.
Using the index access via MOVILINK, user-defined inverter values that cannot be ac-
cessed with GETSYS/SETSYS can also be written/read from IPOS
plus®
. In this way, for
example, the inverter can set the parameters itself in the initialization section.
Before the command is called, initialize the variables that the command uses (command
structure). The beginning of this command structure is transferred to the command as
an argument. The data structure contains the data to be written or read.
Set the parameters for communication in the sender (master) and receiver (slave). The
MOVILINK command is only called in the sender (master).