5
Startup
Assembly and Operating Instructions – Explosion-Proof Gear Units
93
5
Startup
NOTICE
Improper startup may result in damage to the gear unit.
Possible damage to property.
•
Observe the following notes.
•
Before startup, always check to see that the oil level is correct. Refer to the unit's
nameplate for lubricant fill quantities.
•
The oil checking and drain screws and the breather valves must be freely access-
ible.
•
Observe the maximum and r.m.s values of project planning during startup of gear
units with servomotor. The buyer is obliged to make the data available to the end
user.
•
The most important technical data is provided on the nameplate. Additional data
relevant for operation is available in drawings and the order confirmation.
•
After gear unit setup, ensure that all retaining screws are tight.
•
Make sure that the alignment has not changed after tightening the mounting ele-
ments.
•
Prior to startup, ensure that rotating shafts as well as couplings are equipped with
suitable protective covers.
•
If an oil sight glass is used for oil level monitoring, protect it against damage.
•
It is essential that there is no open fire or risk of sparks when working on the gear
unit.
•
Protect the gear unit from falling objects.
•
Remove transport protection prior to startup.
•
Observe the safety notes.
24804134/EN – 05/2018