5
Electrical installation
Improving the grounding (EMC), HF grounding
Operating Instructions – EDR..71 – 315, EDRN63 – 315
61
5.9
Improving the grounding (EMC), HF grounding
For improved, low-impedance grounding at high frequencies, we recommend using
the following connections with corrosion protected connection elements:
HF grounding is not installed as standard.
The HF grounding option can be combined with LF grounding at the terminal box.
If you require LF grounding in addition to HF grounding, you can connect the con-
ductor to the same point.
The HF grounding option can be ordered as follows:
•
Completely pre-assembled at the factory
•
As "grounding terminal" kit for customer installation; part numbers listed in the fol-
lowing table.
Motors
Part number of "Grounding ter-
minal" kit
EDRN63
21014817
EDRS71, EDRN71
EDRE80, EDRN80
21015988
EDRE90, EDRN90
EDRE100M, EDRN100LS
EDRE100L – 132, EDRN100L – 132S
13633945
EDRE160 – 225, EDRN132M – 225
with aluminum terminal box
INFORMATION
If 2 or more ground straps are used, you have to attach them with a longer screw.
The specified tightening torques refer to a strap thickness of t ≤ 3 mm.
25896334/EN – 06/2019