6
Cable specifications
Cable carrier installation
Addendum to the Operating Instructions – AC Motors with MOVILINK
®
DDI Interface
18
6
Cable specifications
6.1
Cable carrier installation
Type
LEHC 005796
LEHC 005770
LEHC 005771
LEHC 005772
LEHC 005773
Part number of bulk
cable, not prefabricated
28123336
28123344
28123352
28123360
28123379
Cross section
4 × 1.5 mm
2
4 × 2.5 mm
2
4 × 4.0 mm
2
4 × 6.0 mm
2
4 × 10 mm
2
Mechanical design
[1]
[2]
[3]
[4]
[5]
[6]
[7]
GNGE
V/L2
W/L3
U/L1
VIO
RS
GE
A
D
C
OR
B
SW
SW
SW
29346392715
[1] Coaxial cable
Coax Z50 in accordance with RG58
Conductor
Stranded copper wire, tinned, 19 × 0.182 mm
Dielectric
Polypropylene Ø 2.95
Shielding
Braided copper wire, tinned, 0.128 mm
Optical coverage at least 90%,
Sheath
TPE
Diameter
4.2 mm
Color
Violet
[2] Cores
2 shielded con-
ductor pairs
2 × 1.0 mm
2
2 shielded con-
ductor pairs
2 × 1.0 mm
2
2 shielded con-
ductor pairs
2 × 1.0 mm
2
2 shielded conductor
pairs
2 × 1.5 mm
2
Shielded element
4 × 1.5 mm
2
Stranded copper wire, bare
Single wire 0.15 mm
in accordance with DIN EN 60228 class 6
IEC 60228 Class 6
Insulation
Polypropylene
Shielding
Braided copper
wire, 0.10 mm,
tinned
Braided copper
wire, 0.10 mm,
tinned
Braided copper
wire, 0.10 mm,
tinned
Braided copper wire,
0.10 mm, tinned
Braided copper wire,
0,128 mm, tinned
Optical coverage at least 85%
Diameter
2.1 mm
2.1 mm
2.1 mm
2.4 mm
2.4 mm
Colors
Yellow with black label A
Orange with black label B
Pink with black label C
Purple with black label D
[3] Banding
-
[4] Filler
-
29182654/EN – 10/2019