56
Operating Instructions – AC Motors DR / DV / DT / DTE / DVE / Asynchrounos Servo Motors CT / CV
9
Operating currents
Technical Data
BMG 05 - BMG 4
brake
Key
BMG05
BMG1
BMG2
BMG4
Motor size
71/80
80
90/100
100
Max. braking torque [Nm]
5
10
20
40
Braking power [W]
32
36
40
50
Inrush current ratio I
B
/I
H
4
4
4
4
Rated voltage V
N
BMG05
BMG 1
BMG 2
BMG 4
I
H
[A
AC
]
I
G
[A
DC
]
I
H
[A
AC
]
I
G
[A
DC
]
I
H
[A
AC
]
I
G
[A
DC
]
I
H
[A
AC
]
I
G
[A
DC
]
V
AC
V
DC
24
1.38
1.54
1.77
2.20
24 (23-25)
10
2.0
3.3
2.4
3.7
-
-
-
-
42 (40-46)
18
1.14
1.74
1.37
1.94
1.46
2.25
1.80
2.80
48 (47-52)
20
1.02
1.55
1.22
1.73
1.30
2.00
1.60
2.50
56 (53-58)
24
0.90
1.38
1.09
1.54
1.16
1.77
1.43
2.20
60 (59-66)
27
0.81
1.23
0.97
1.37
1.03
1.58
1.27
2.00
73 (67-73)
30
0.72
1.10
0.86
1.23
0.92
1.41
1.14
1.76
77 (74-82)
33
0.64
0.98
0.77
1.09
0.82
1.25
1.00
1.57
88 (83-92)
36
0.57
0.87
0.69
0.97
0.73
1.12
0.90
1.40
97 (93-104)
40
0.51
0.78
0.61
0.87
0.65
1.00
0.80
1.25
110 (105-116)
48
0.45
0.69
0.54
0.77
0.58
0.90
0.72
1.11
125 (117-131)
52
0.40
0.62
0.48
0.69
0.52
0.80
0.64
1.00
139 (132-147)
60
0.36
0.55
0.43
0.61
0.46
0.70
0.57
0.88
153 (148-164)
66
0.32
0.49
0.39
0.55
0.41
0.63
0.51
0.79
175 (165-185)
72
0.29
0.44
0.34
0.49
0.37
0.56
0.45
0.70
200 (186-207)
80
0.26
0.39
0.31
0.43
0.33
0.50
0.40
0.62
230 (208-233)
96
0.23
0.35
0.27
0.39
0.29
0.44
0.36
0.56
240 (234-261)
110
0.20
0.31
0.24
0.35
0.26
0.40
0.32
0.50
290 (262-293)
117
0.18
0.28
0.22
0.31
0.23
0.35
0.29
0.44
318 (294-329)
125
0.16
0.25
0.19
0.27
0.21
0.31
0.25
0.39
346 (330-369)
147
0.14
0.22
0.17
0.24
0.18
0.28
0.23
0.35
400 (370-414)
167
0.13
0.20
0.15
0.22
0.16
0.25
0.20
0.31
440 (415-464)
185
0.11
0.17
0.14
0.19
0.15
0.22
0.18
0.28
500 (465-522)
208
0.10
0.15
0.12
0.17
0.13
0.20
0.16
0.25
I
B
Accelerator current – brief inrush current
I
H
Holding current r.m.s. value in the connecting harness to the SEW brake rectifier
I
G
Direct current with direct DC voltage supply
V
N
Rated voltage (rated voltage range)
P
i
f
kVA
Hz
n