Manual – MOVI-PLC® advanced DHR41B for EtherNet/IP, Modbus/TCP and PROFINET IO
27
5
Settings in MOVI-PLC® advanced DHR41B
Configuration and Startup (EtherNet/IP)
5.3
Settings in MOVI-PLC
®
advanced DHR41B
The creation of IEC programs is described in detail in the "MOVI-PLC
®
" manual. This
section only describes the fieldbus-specific characteristics.
5.3.1
Process data configuration
The process data interface is normally configured by the master (scanner). It sets the
number of process data words and the timeout interval.
In the parameter tree of MOVITOOLS
®
MotionStudio (index 8451), the currently set val-
ue is displayed in the field "PD configuration" (see following figure).
5.3.2
Status of the fieldbus interface
The function module
FbusGetInfo
makes the status and some display parameters of the
fieldbus interface available for the IEC program and diagnostics.
If there is no communication with the fieldbus master, the output
Error
is set to
TRUE
.
During an active fieldbus connection, the output
Done
is set to
TRUE
, and the outputs
Address
,
Baud rate
,
Timeout
and
Bus type
show the respective parameters as they
were set via the DIP switches of the DHR41B option or via the PLC.