Manual – MOVI-PLC® advanced DHR41B for EtherNet/IP, Modbus/TCP and PROFINET IO
107
11
Parameterization via PROFIdrive data record 47
Operating Behavior (PROFINET IO)
11.3.4 Controller processing sequence
If the bus cycles are very short, the request for the parameter response arrives before
the SEW device has concluded the parameter access in the device. This means that the
response data from the SEW device is not yet available. In this state, the device delays
the response to the
Read Record Request
.
62209AEN
Send Write.request
with parameter data
Send Read.request
Check Write.
response
Write.response
negative
Write.response
positive
Parameter transfer
aborted with ERROR
Read.response
negative or
Yes
No
Parameter transfer
ok, data available
timeout
0
0
I