8
Operation
DHR21B/41B controller
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
69
Status LED
Status
Meaning
Red, flashing every
125 ms
BUS WARNING
The device is performing a DUP-MAC
check and cannot send any messages
because no other stations are connec-
ted to the bus (error passive state).
Red, flashing with 1 Hz
BUS WARNING
The number of physical bus errors is
too high. No more error telegrams are
actively written to the bus (error pass-
ive state).
Red
BUS ERROR
•
BusOff state
•
The number of physical bus errors
has increased despite switchover
to error-passive state. Access to
the bus is switched off.
Yellow
POWER OFF
External voltage supply has been
turned off or is not connected.
8.3
DHR21B/41B controller
The DHR21B/41B controller comes equipped with 4 LEDs (L11 – L14) that indicate
the present state of the controller in EtherNet/IP and MODBUS/TCP mode.
No.
Name
Function in EtherNet/IP and Modbus/
TCP mode
LED 11
–
Reserved
LED 12
–
Reserved
LED 13
Network status
Network status
LED 14
Module status
Module status
No.
Name
Function in PROFINET mode
LED 11
–
Reserved
LED 12
–
Reserved
LED 13
BUS FAULT
Bus error
LED 14
RUN
Bus running
8.3.1
LEDs in PROFINET mode
LED "L13" (BUS FAULT)
LED "L13" (BUS FAULT) indicates the PROFINET state.
Status LED
Possible cause
Measure
Off
PROFINET IO device is exchanging
data with the PROFINET IO controller
(Data Exchange).
–
•
Flashing green
•
Flashing green/red
The flashing function in the
PROFINET IO controller configuration
is activated to visually localize the sta-
tions.
–
22900055/EN – 08/2016