Startup procedure for MDX61B with DFE32B option
Project Planning with PROFINET
5.5
Startup procedure for MDX61B with DFE32B option
The following sections will describe the the startup procedure for a MOVIDRIVE
®
B with
the DFE32B PROFINET IO option step-by-step.
5.5.1
Preliminary work
Step 1: Install the required software
1. FTDI driver for USB11A programming interface
– Connect USB11A to the PC. Windows hardware detection installs the required
FTDI driver.
– The FTDI driver is available on the Software ROM 7 or on the SEW website.
2. GSD file: SEW-DFE32B-2-Port_V2.1-JJJJ.MM.TT.xml
3. MOVITOOLS
®
MotionStudio version 5.40 or later.
Step 2: Installing the devices
1. Install MOVIDRIVE
®
MDX60B/61B according to operating instructions:
– Supply system cable
– Motor cable
– Braking resistor
– DC 24 V backup voltage
2. Install PROFINET and connect DFE32B to PROFINET.
5.5.2
Starting up MOVIDRIVE
®
B with DC 24 V or AC 400 V
Step 1: Configuring MOVIDRIVE
®
B
1. Start MOVITOOLS
®
MotionStudio and open a new project.
Specify a project name and assign USB11A programming interface according to se-
rial COM interface.
– When the USB11A programming interface is connected to the PC for the first
time, Windows hardware detection installs the required FTDI driver
– If USB11A is not recognized, check the assignment to the COM interface. The
matching COM port is marked by "USB".
2. Connect the PC to MOVIDRIVE
®
B via USB11A programming interface.
3. Perform a unit scan. To do so, select the unit using the mouse button and make a
right-mouse click to open the context menu. Then choose [Startup] / [Parameter tree]
from the menu.
4. Set
P100 setpoint source
and
P101 control signal source
to "Fieldbus".
5. For simple control via fieldbus, the binary inputs can be set to "No Function" via pa-
rameters P601 ... P608.
6. Check the parameterization for the process data (P87x). The parameters for control
word and status word must be set. Set
P876 PO data enable
to "Yes".