![SEW-Eurodrive CMP40 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/sew-eurodrive/cmp40/cmp40_operating-instructions-manual_1250217029.webp)
Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
29
5
Connector installation
Electrical Installation
5.7
Connector installation
The cable entry of the power and signal cable is installed using an adjustable right-angle
connector. Once the mating connector has been plugged in, the right-angle connector
can be adjusted as required without using additional tools. A torque of approximately
10 Nm is required to adjust the connector.
5.7.1
Connector positions
An [adjustable] position has been defined for right-angle, rotatable connectors. This is
the standard connector position. It corresponds to connector position "3".
A "radial" position has been defined for the straight connector housing (radial output).
Radial connectors [2] are optional.
STOP!
If the connector is tightened when it is installed in the wrong position, the insulator could
slip, causing irreparable damage.
Potential damage to property!
Note the following when plugging in the power and signal connectors:
• Check that the connector is installed in the correct position.
• Check that the detent on the connector is positioned correctly.
• Make sure that the connector lock can be turned without having to apply too much
force.
58840AXX
[1]
Connector position "adjustable"
[2]
Connector position "radial"
[1]
[2]
NOTE
Comply with the permitted bending radii of the cables.