5
Electrical installation
Electrical connections
Operating Instructions – CMP ELVCD
32
5.8.3
X1: DC 24 V input, DC 48 V input, and digital inputs/outputs
Function
•
DC 24 V input for unit electronics supply
•
DC 48 V input for DC link supply
•
Digital inputs/outputs
Connection type
Phoenix VARIOCON with 18 contacts
Module A
Connection image
C
B
A
8 7 6 5
4 3 2 1
No.
Name
Function
1
DO00
Digital output DO00, ready for operation
2
DI8
Digital input DI08, limit switch right/positive (locks at
n > 0, clockwise rotation)
3
DI05
Digital input DI05, no function/transparent
4
DI03
Digital input DI03, no function/transparent
5
DI09
Digital input DI09, switch on output stage
6
DI07
Digital input DI07, limit switch left/negative (locks at
n < 0, counterclockwise rotation)
7
DI04
Digital input DI04, no function/transparent
8
DI02
Digital input DI02, no function/transparent
Module B
Connection image
C
B
A
8 7 6 5
4 3 2 1
No.
Name
Function
1
DI01
Digital input DI01, no function/transparent
2
DO02
Digital output DO02, parameterizable (Parameter de-
scription)
3
res.
Reserved
4
GND
Reference potential for binary signals
5
DI00
Digital input DI00, no function/transparent
22759468/EN – 11/2017