SEVERIN DOUBLE DOOR KS 9761 Скачать руководство пользователя страница 1

12

Refrigerator 

Dear Customer,

Before using the appliance, please read the following 

instructions carefully and keep this manual for future reference. 

The appliance must only be used by persons familiar with these 

instructions.

Connection to the mains supply 

The appliance should only be connected to an earthed socket 

installed in accordance with the regulations. Make sure that 

the supply voltage corresponds with the voltage marked on the 

rating label. This product complies with all binding CE labelling 

directives.

 

 Do not operate this unit by means of a transformer.

 

 To prevent noise vibration, ensure that the power cord does 

not touch any part of the rear of the unit 

General information

 

 This  appliance is a compressor refrigerator, designed for the 

short-term storage of food in the main cabinet and long-term 

storage of food in the freezer compartment.

 

 Refrigeration appliances are classi

fi

 ed into certain climate 

classes. Please refer to the product data sheet for 

information on the classi

fi

 cation for this unit; the data sheet 

can be found at the end of this manual.

 

 No responsibility is accepted if damage results from 

improper use, or if these instructions are not complied with. 

Important safety instructions

 

 This appliance is intended for domestic 

or similar applications, such as 

 -in shops, of

fi

 ces and other similar 

working environments,

 -in agricultural areas,

 -by customers in hotels, motels etc. and 

similar establishments,

 -in bed-and breakfast type 

environments.

 

 This appliance is not intended for 

commercial use, nor for use in the 

catering business or similar wholesale 

environments.

 

 

The cooling circuit in 

this appliance 

contains the 

refrigerant isobutane 

(R600a), a natural gas 

with a high level of environmental 

compatibility, which is nevertheless 

fl

 ammable. Ensure, therefore, that none 

of the components of the refrigerant 

circuit become damaged during 

transportation and installation of the 

appliance. If damage to the cooling 

circuit does occur, do not switch on or 

connect the appliance to the mains 

power.  In the case that there is an open 

fi

 re or any other sources of ignition in the 

vicinity of the refrigerant gas, make sure 

it is removed immediately from this area 

and that the room is then thoroughly 

ventilated.

 

 

Warning:

  Keep ventilation openings, in 

the appliance enclosure or in the built-in 

structure, clear of obstruction.  Suf

fi

 cient 

ventilation must be ensured at all times.

 

 

Warning:

  Do not damage the cooling 

circuit. Any escaping refrigerant causes 

damage to the eyes;  there is also a 

danger of the gas igniting.

 

 

Warning:

  Do n ot use any external 

device (e.g.; heaters or heating fans) to 

accelerate de-frosting;  follow only the 

methods recommended in this manual. 

 

 

Warning:

  Do not operate any electrical 

appliances (e.g. ice makers) inside 

the storage compartment that are 

not speci

fi

 cally permitted in these 

instructions. 

 

 Before it is connected to the mains 

power, the unit must be thoroughly 

checked for transport damage, including 

its power cord. In the event of any such 

damage being found, the appliance must 

not be connected to the mains.

 

 This appliance is not designed for the 

GB

Содержание DOUBLE DOOR KS 9761

Страница 1: ...akfast type environments This appliance is not intended for commercial use nor for use in the catering business or similar wholesale environments The cooling circuit in this appliance contains the ref...

Страница 2: ...the appliance must no longer be used To avoid the risk of fire do not place any thermo electric appliances on top of the unit Do not place liquid containers on top of the unit to prevent any leaking o...

Страница 3: ...r once the cooling process has begun Installation The appliance should be set up in a well ventilated dry room It should be operated in conditions where the relative humidity is no more than 70 The pr...

Страница 4: ...emove both screws on the left of the underside and replace them on the right Fit the lower hinge bracket 14 on the left of the underside Put the washers on the hinge pin Remove the cap 19 from the fre...

Страница 5: ...aution Do not exceed the maximum freezing capacity per day The product data sheet at the end of this manual contains details of the maximum daily freezing capacity Set the temperature control to Max t...

Страница 6: ...of ice inside the freezer compartment has reached a thickness of 2 4 mm it needs to be de frosted This should be done at least twice a year Ensure that the plug has been removed from the wall socket...

Страница 7: ...from the date of purchase Under this guarantee the manufacturer undertakes to repair or replace any parts found to be defective providing the product is returned to one of our authorised service centr...

Страница 8: ...16 38 Noise emission in dB a 39 Dimensions H x W x D in mm 1440 x 560 x 600 1690 x 560 x 630 1440 x 560 x 600 Weight kg 45 50 45 Electrical specifications See rating plate In accordance with EU direc...

Отзывы: