6. Menu / Operation
46
6.3.12.16 Flap monitoring (option) (menu item requires login)
- Select "Flap monitoring" with
.
Flap monitoring can be configured in this menu.
0.0s deactivates the monitoring.
Values different to 0 set the time, which the flap may not extend when
switching from normal position to reject position and vice versa.
The value can be varied in steps of 0.1s up to a maximum of 10.0s.
Changing the factory pre-set value is usually not required.
6.3.12.17 External error (option) (menu item requires login)
- Select "External error" with
.
This menu item is used to configure the external error input.
[x] Activated
[ ] Deactivated
The error signal only is accepted after the set delay time (error filter).
The value can be set up to 25.0s in 0.05s steps.
6.3.12.18 Ejection monitoring (option) (menu item requires login)
- Select "Ejection monitoring" with
.
In the ejection monitoring menu item the input, depending on the applica-
tion, can be assigned different functions, e.g. level monitoring.
This item is used to configure level monitoring.
[x] Activated
[ ] Deactivated
- Level monitoring
Shows whether the reject container still has free capacity.