Control
34
Menus
ADDDIF TEMP
Additional electrical heater restart determined by water temperature degeneration: it is adjustable from 1 to
10 degree (factory setting is 4 degree); the electrical heater will stop when the water get to setting
temperature, then restarts as soon as the water temperature decrease 4 degree (factory setting)
OUTADD.HEAT ON (OFF)
To control outdoor unit electrical heater (bottom electrical heater, evaporator heater), factory setting is ON,
the heater will start when ambient temperature is less than 0 ˚
ɋ
, and stop when ambient temperature is
more than 2˚
ɋ
When the outdoor electrical heater is select OFF, the outdoor heater can not start automatically.
Display : OUT ADD . HEAT OFF
ADD DELAY : ( 3 to 90 Min adjustable , factory setting is 30M )
ADD START : ( 10 to 65 degree adjustable , factory setting is 45 degree )
Electrical heater start water temperature, it is adjustable from 10 - 65°C, factory setting is 40°C, this
means when compressor heat the water temperature over 40°C, then allow the electrical heater to start,
this setting is for energy-saving and water tank heating (WARMWATER) only.
HDO ON ( )
Choose "
" to activate the function 'External signal controls heat pump to start or stop'; there are two
signal connections (NC), when external signal switch on them, the compressor, electrical hearer and motor
will stop running (The water pump will keep running if the operation mode is 'Room heating'); After switch
off them, the compressor, electrical heater, motor will restart and work as previous setting.
This function is for the countries which electricity has two different prices in high peak and low peak that
peak electricity;
they can use signal to stop heat pump when in high peak electricity and start the heat pump when in low
Notice: never input electricity directly to HDO terminals!
Sub-Menu
OPERATING TIME
OPERATION
TIME
HEATPUMP
ADD 1
0
H
0
H
ADD 2
0
H
ADD 3
0
H
Menu Text
Description
Adjustable by
HEATPUMP
Total operating hours of heat pump since installation.
Operating time will not be reset to zero.
ADD
Total operating hours of auxiliary heater 1
(3kW) since installation. Operating time will
not be reset to zero.
can not
can not