MOTOR AND FOUNDATION BOX PARTS

230V~

3x1,5 

mm²

4  x 0,5 

mm²

2  x 0,5 

mm²

4  x 0,5 

mm²

4  x 1,5 

mm²

2  x 0,5 

mm²

3 x 0,5 

mm²

RG58 + 2 X 0,75 

mm²

2

4

5

5

6

3

1

4  x 1,5 

mm²

1

SEALING RING

THREADY PINS TO HOUSE THE MOTOR

 GUIDE SHOE

 GEARED MOTOR
 

 CAPACITOR

FOUNDATION BOX

!

STIRRUP WITH UNCLAMPING

COVER

M

C

/5

C

 I

  

E

IMPORTANT: 
GREASE THE PIVOT 
BEFORE FITTING THE 
LEVER GROUP

4

M/10 electric key

5

Pair of P/10 photocells

6

RZ/20 F Flashing light with antenna 

1

Geared motor + f

 MC/5C

2

CR/41 electronic control unit with built-in receiver

3

OG/62 2-channel minitransmitter 

oundation box

STANDARD INSTALLATION

Advice for wiring up in non-specialised environments.

1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or, 

alternatively, use a 10A thermal magnetic circuit breaker.

2. Always make connections, of any type, with the system disconnected from the power supply, i.e. with the main switch 

set to OFF (symbol “0”). The control unit, in particular, must never be connected to the power supply either during the 
wiring up, or when fitting any expansion boards.

3. The following cables must be used for installation of the system: 

2

2

- for the control unit, motor and electric lock power supplies: 1.5mm  section for lengths of up to 19m, 2.5mm  section 

for lengths of up to 31m,

2

2

- for the flashing light: 0.75mm  section for lengths of up to 3m, 1.5mm  section for lengths of up to 19m,
- for the low voltage and current lines, (e.g. for the photocells, control buttons, electromechanical key, sensitive 

2

2

edges and other safety devices: 0.5mm  section for lengths of up to 50m, 0.75mm  section for lengths of up to 100m.

4. Wire up the earth connection in compliance with legal provisions.